6.
Mode: Record mode. Modes supported by the corresponding models are listed as follows.
Models
AS04AD-A
AS06XA-A
AS02ADH-A
(1)
Fixed period mode: Set Mode=0, the data recording would be performed according to the pre-defined record
period when EN switches to ON. After the recording of a specified number of log points is complete, the Cmplt
flag would be set to High automatically.
Example:
_6
Set Points = 2000
CurNo
Cmplt
(2)
Fixed period + Trigger start mode: Set Mode=1 and switch instruction EN to ON before the recording starts.
When a trigger signal is detected at the external input point, start recording based on the pre-defined record
period. And the Cmplt flag is set to High automatically when completed. Before the recording is complete, any
operation at the external input points does NOT affect the proceeding of record. When the recording of log points
is complete and the Cmplt flag is High, trigger the external input points again to start a new cycle of recording;
the instruction EN does NOT required to be turned OFF and then ON again to start another new recording.
6-526
Mode
Mode name
K0
Fixed period
K0
Fixed period
K1
Fixed period + Trigger start
K2
Point logging
Fixed period + Trigger position
K3
assign
1
200 0 poin ts
0
EN
0
1~1999
Description
Perform recording periodically.
Perform recording periodically.
Wait for trigger signal detected at external input
points. After received, periodic recording would
be performed.
No fixed period for recording. One log point
would be recorded each time a trigger signal is
detected at the external input point.
You can specify the external trigger timing to
record the data logs during the periods before
and after the trigger timing.
2
200 0 poin ts
2000
0~1999
t
2000