ErrCode
16#1405
Input interface not selected. Instruction stops.
16#1406
Invalid value in Action
16#1409
Invalid value in Yno
One of the counting channel of the HC module is executing output. Other channels cannot
16#1413
perform the same task at the same time.
Example 1: Output from the output point Y when the counter value reached the set value.
1.
In HWCONFIG set the input interface of the channel 1 to pulse input or SSI input. And set the counter type to ring
counter.
2.
Set the value in Comp 1 to 16#5000000, the value in Action1 to 3, and the value in Yno1 to 0; set the value in
Comp 2 to 16#D000000, the value in Action2 to 3, and the value in Yno2 to 1.
3.
When M0 = ON, the counter starts counting and sets parameters for DHCCMP instruction and then waits for the
counter value to meet the set value.
4.
When the counter value reached Comp 1, the Match 1 flag is ON. Y0.0 is OFFON.
5.
When the counter value reached Comp 2, the Match 2 flag is ON. Y0.1 is OFFON.
6.
When the counter value reached Comp 1 once again, Y0.0 is ONOFF. When the counter value reached Comp 2
once again, Y0.1 is ON
OFF.
Cha p ter 6 App l ied Ins truc tio ns
Description
6_
6-507