Delta AS Series Programming Manual page 1111

Hide thumbs Also See for AS Series:
Table of Contents

Advertisement

AS Ser ies Pro gra mm in g M anu al
Operand
S
3
S
4
S
5
S
6
S
7
S
8
_6
_6
S
9
S
10
2.
In general, the SCONFP pulse instruction is used.
3.
The Socket parameters uses the setting values in HWCONFIG by default. Use the SCONFP instruction when the
parameters need to be changed during communication.
4.
If you set the parameters while the socket is communicating, the settings do not take effect until the communication
is complete. The setting should be changed after the socket is no longer in use.
5.
If any one of the parameters is out of range, the instruction is not executed, SM0 is ON, and the error code in SR0
is 16#2003.
6 - 8 3 2
Name
The first two sections of the IP address occupy
the first word and the remaining two sections
Remote IP address
of the IP address occupy the second word. For
example, if the IP address is 192.168.1.5,
S
=16#C0A8 and S
3
Remote port
Range: 0–65535; 0 indicates any port
Local port
Range: 0–65535; 0 indicates any port
Specifies the number of a D device. Range: 0–
Register where
29999. Example: The setting value 100 means
sent data comes
S
bytes of data are sent from the registers
7
from
starting at D100 (from the low byte to the high
byte).
Maximum: 512 bytes
Size of sent data
For PLC with FW V1.06.30 or later; maximum:
4096 bytes
Specifies the number of a D device. Range: 0–
Register where
29999. Example: The setting value 200 means
received data is
S
bytes of data are received and stored in the
9
stored
registers starting at D200 (from the low byte to
the high byte).
Maximum: 512 bytes
Size of received
For PLC with FW V1.06.30 or later; maximum:
data
4096 bytes
Connection time
Range: 1–30000, unit: second
Description
+1=16#0105.
3
Data Type
Remarks
Occupies
two
WORD[2]
consecutive
words
WORD
WORD
WORD
WORD
WORD
WORD
Applicable
WORD
to TCP
mode only