[Pr. PF40_Machine failure prediction servo parameter (MFPP)]

Initial value
00000000h
[Pr. PF40.0_Friction failure prediction - Threshold multiplication]
Initial value
0h
Set a multiplying factor for calculating the threshold used in the friction failure prediction function.
The smaller the multiplying factor for the friction failure prediction threshold, the smaller the threshold used for friction failure
prediction, which makes it easier to predict failure earlier, but also increases the possibility of erroneous detection.
When "0" is set, the threshold multiplying factor is 5.
[Pr. PF40.1_Vibration failure prediction - Threshold multiplication]
Initial value
0h
Set a multiplying factor for calculating the threshold used in the vibration failure prediction function.
The smaller the multiplying factor for the vibration failure prediction threshold, the smaller the threshold used for vibration
failure prediction, which makes it easier to predict failure earlier, but also increases the possibility of erroneous detection.
When "0" is set, the threshold multiplying factor is 5.
[Pr. PF40.2_Friction failure prediction - Dynamic friction selection]
Initial value
0h
Select the dynamic friction to use for friction failure prediction.
0: Automatic setting
1: Dynamic friction at forward rotation torque (at rated speed)
2: Dynamic friction at reverse rotation torque (at rated speed)
3: Absolute value average at forward rotation/reverse rotation torque
When set to "0", the value changes to any of "1" to "3", depending on the operation pattern.
[Pr. PF40.4_Static friction failure prediction - Threshold multiplication]
Initial value
0h
Set a multiplying factor for calculating the threshold used in the static friction failure prediction function.
Setting a small threshold multiplication for static friction failure prediction will decrease the threshold used for static friction
failure prediction. Thus, this will enable the prediction of a failure at an early stage, but will increase the possibility of
erroneously detecting a failure.
When "0" is set, the threshold multiplying factor is 5.
[Pr. PF40.5_Static friction failure prediction - Static friction selection]
Initial value
0h
Select the static friction setting to use for static friction failure prediction.
0: Automatic setting
1: At forward rotation torque
2: At reverse rotation torque
3: Average at forward rotation/reverse rotation torque
When set to "0", the value changes to any of "1" to "3", depending on the operation pattern.
1 SERVO PARAMETER DETAILS
126
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Setting range
Refer to the relevant detail No.
Setting range
0h to Fh
Setting range
0h to Fh
Setting range
Refer to the text
Setting range
0h to Fh
Setting range
Refer to the text
Setting method
Each axis
Ver.
A0
Ver.
A0
Ver.
A0
Ver.
A0
Ver.
A0
Ver.
Refer to the relevant detail No.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Mr-j5w-g

Table of Contents