[Pr. PF25_SEMI-F47 function - Instantaneous power failure
detection time (Instantaneous power failure tough drive detection
time) (CVAT)]
Initial value
200 [ms]
Set the time until the occurrence of [AL. 010.1 Voltage drop in the control circuit power].
To comply with SEMI-F47 standard, it is not required to change the time from the initial value (200 ms).
When the instantaneous power failure time exceeds 200 ms, and the instantaneous power failure voltage is less than 70 % of
the rated input voltage, the power may be turned off normally even if a value larger than 200 ms is set in this servo parameter.
This function is disabled when [Pr. PA20.2 SEMI-F47 function selection] is set to "0" (disabled).

[Pr. PF29_Function selection F-10 (*FOP10)]

Initial value
00000000h
[Pr. PF29.1_State selection with forced stop in progress]
Initial value
0h
Select the PDS state transition for when the forced stop is in progress.
When the servo amplifier detects the forced stop signal off during servo motor rotation, the PDS state transition destination
can be selected.
0: Operation enabled
1: Quick stop active
1 SERVO PARAMETER DETAILS
122
1.7 Extension setting 3 servo parameters group ([Pr. PF_ _ ])
Setting range
30 to 500
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
Setting method
Common
Setting method
Each axis
Ver.
B2
Ver.
A0
Ver.
Refer to the relevant detail No.