[Pr. Pt19_Position Range Output 1 Address + (*Lpp1)]; [Pr. Pt21_Position Range Output 1 Address - (*Lnp1)] - Mitsubishi Electric MR-J5-G User Manual

Hide thumbs Also See for MR-J5-G:
Table of Contents

Advertisement

[Pr. PT19_Position range output 1 address + (*LPP1)]

Initial value
0 [Refer to the text below for the unit.]
Set the address increasing side of the position range output 1 address.
Use this servo parameter and [Pr. PT21 Position range output 1 address -] to set the range where position range 1 (POT1)
turns on.
This function is enabled in the profile position mode and positioning mode (point table method).
The unit can be changed to 0.001 mm, 0.0001 inch, 0.001 degree or pulses with [Pr. PT01.2 Unit for position data].
If [Pr. PT19] is set to a value less than [Pr. PT21] while [Pr. PT01.2] is set to "3" (pulse), [AL. 037 Parameter error] occurs.
When [Pr. PT01.2] is set to "2" (degree), set [Pr. PT21] as the starting point and [Pr. PT19] as the ending point.
An example setting of the degree unit is as follows.
The output range is the section where the servo motor moves from "-" to "+" in the CCW direction.
CCW
Moving range A
90 [degree]
Moving range B
Set the output range of moving range A as follows:
• [Pr. PT21] = 315.000 degrees
• [Pr. PT19] = 90.000 degrees
Set the output range of moving range B as follows:
• [Pr. PT21] = 90.000 degrees
• [Pr. PT19] = 315.000 degrees
The setting range is 0 to 359.999 degrees. If a value out of the setting range is set, the value will be converted as shown in the
table below.
The values of the output range shown above will be the values after conversion.
Setting value
360.000 to 2147483.647 degrees
-0.001 to -359.999 degrees
-360.000 to -2147483.648 degrees

[Pr. PT21_Position range output 1 address - (*LNP1)]

Initial value
0 [pulse]
Set the address decreasing side of the position range output 1 address.
The other specifications are the same as [Pr. PT19 Position range output 1 address +].
1 SERVO PARAMETER DETAILS
162
1.9 Positioning control setting servo parameters group ([Pr. PT_ _ ])
Setting range
-2147483648 to 2147483647
0 [degree]
315 [degree]
After conversion
The remainder obtained by dividing the setting value by 360.000
The value obtained by adding 360.000 to the setting value
The value obtained by adding 360.000 to the remainder after dividing the setting value by 360.000
Setting range
-2147483648 to 2147483647
Setting method
Each axis
Setting method
Each axis
Ver.
A5
Ver.
A5