[Pr. PL17_Magnetic pole detection - Minute position detection
method - Function selection (LTSTS)]
Initial value
00000000h
This servo parameter is enabled when [Pr. PL08.0 Magnetic pole detection method selection] is set to "4" (minute position
detection method).
[Pr. PL17.0_Response selection]
Initial value
0h
Select the responsiveness of the minute position detection method.
To make the travel distance at the magnetic pole detection smaller, set a larger value.
Refer to the following table for setting values.
Setting value of [Pr. PL17.0]
0
1
2
3
4
5
6
7
8
9
A
B
C
D
E
F
Setting range
Refer to the relevant detail No.
Setting range
Refer to the text
1.8 Motor extension setting servo parameters group ([Pr. PL_ _ ])
Setting method
Each axis
Ver.
A0
Responsiveness
Low response
Middle response
High response
1 SERVO PARAMETER DETAILS
Ver.
Refer to the relevant detail No.
153