[Pr. PD22_Driver communication setting - Slave - Master axis 1 -
Station No. setting ( *SM1N)]
Initial value
0
Set the station No. of master axis 1.
This servo parameter is enabled when it is set as the slave axis (when [Pr. PD15.1] is set to "1").
When "0" is set, this servo parameter is disabled.
[Pr. PD23_Driver communication setting - Slave - Master axis 1 -
Transmission and receive setting ( *SM1C)]
Initial value
00000000h
[Pr. PD23.1_Driver communication setting - Slave - Master axis 1 - Control slave axis
No. setting]
Initial value
0h
Set the control slave No. for master axis 1.
This servo parameter is enabled when it is set as the slave axis (when [Pr. PD15.1] is set to "1").
To set the servo amplifier as a control slave axis, set any value from "1" to "8". When "0" is set, this servo amplifier being used
will not function as a control slave axis.
Setting range
0 to 255
Setting range
Refer to the relevant detail No.
Setting range
0h to 8h
Setting method
Each axis
Setting method
Each axis
Ver.
D0
1 SERVO PARAMETER DETAILS
1.5 I/O setting servo parameters group ([Pr. PD_ _ ])
Ver.
D0
Ver.
Refer to the relevant detail No.