Port Properties; General Port Properties; Configuration Port Properties - Compaq Armada 6500 Hardware And Software Manual

Hp armada 6500: software guide
Hide thumbs Also See for Armada 6500:
Table of Contents

Advertisement

3-6 Compaq Storage Hub 12 Management Utilities Hardware and Software User Guide

Port Properties

General Port Properties

Configuration Port Properties

Selecting Port Properties in the menu pulls up a window with two tabbed
pages that offer detailed information and control over a selected port.
The information shown in the General Port Properties screen is specific to
the port chosen. This screen offers information about active or inactive ports,
the management protocol in use, and more.
The error counters are essential for analyzing events. If any of these counters
begin to accumulate occurrences too rapidly, check the device attached to that
port. Sometimes the rapid accumulation may only indicate that the device has
been disconnected and reconnected which can be typical in a SAN. However,
if devices have not been disconnected or reconnected, it might be due to a
problem with a device issuing invalid LIPs.
The Operating Mode options are as follows:
Force Bypassed - By checking or unchecking Forced Bypassed for a
port, that port will be forced bypassed or enabled, respectively. When a
port is in forced bypassed mode, a device may be connected to the port,
but it will not be allowed into the loop. If a port is enabled and a device
is attached to that port, that device will be allowed to enter the loop
(assuming that other management features such as Authorized Cut-In
are not disallowing the device's access to the loop).
Authorized Cut-in - A new device added should be checked before
being added. Sometimes a fully operational device has been plugged
into a specific port, yet disallowed from being part of the network until
manually authorized. In that case, a window appears and gives
permission for the new device to join the network.
Single Fiber Failure Detection - If this port is connected to another
hub, this option would detect the loss of a single fiber between the two.
If this occurs, the two hubs isolate themselves from each other, but still
function independently (effectively as two separate networks) until the
problem is repaired. Since the two hubs periodically try to rediscover
each other, they will reconnect automatically when the problem is fixed.

Advertisement

Table of Contents
loading

This manual is also suitable for:

Storage hub 12 management utilities

Table of Contents