Toshiba TS3000 Series Instruction Manual page 123

Robot controller
Hide thumbs Also See for TS3000 Series:
Table of Contents

Advertisement

series Robot Controller
Preparation
In order to use the bypass function, it is necessary to enable the bypass function and
set the bypass distance in the Z-axis direction in [U23] Bypass function parameter of the
user parameter file in advance.
The meanings of the user parameters and sample settings are shown below.
* For details on parameter editing procedures, please see Section 6.
User parameter file
 BYPASS function
{ Function enable SW }
= 1
When using the TP3000, set either "1" or "2".
 Retract position parameter
(for SCARA robot)
{ Retract position }
= 0.0 0.0
Enter the bypass distance in a
numeric value (absolute position) in
Item 3 (Z axis).
Other items are not used by SCARA
robots. Even if numeric values are
defined, they will not take effect.
[U23] Bypass function parameter
{ Function enable SW (0:Disable, 1:M-to & Bypass,
= 1
= 0.0
0.0
200.0
= 0.0
0.0
Enable/Disable setting
200.0 0.0 0.0 0.0
5-22
TP3000
0.0
0.0
0.0
STE 85412