8.1 Parameter definitions

The servo drive parameters are divided into eight groups. The first character after the start code
P is the group number and the following three characters are the parameter indicator.
8
The communication address is the combination of the group number and the three-digit number,
expressed in hexadecimal. The parameter groups are:
Group 0: Monitoring parameters (Example: P0.xxx)
Group 1: Basic parameters (Example: P1.xxx)
Group 2: Extension parameters (Example: P2.xxx)
Group 3: Communication parameters (Example: P3.xxx)
Group 4: Diagnosis parameters (Example: P4.xxx)
Group 5: Motion control parameters (Example: P5.xxx)
Group 6: PR parameters (Example: P6.xxx)
Group 7: PR parameters (Example: P7.xxx)
Control mode description:
PT: Position control (command input through terminal block)
PR: Position control (command sent from internal register)
S: Speed control
T: Torque control
Special symbol description:
Icon of parameter
property
8-2
Read-only parameter. Can only read the value of the parameter.
For example, P0.000, P0.010, and P4.000.
Parameter cannot be changed when servo is in Servo On status.
For example, P1.000 and P1.046.
Parameter changes become valid after power cycling.
For example, P1.001 and P3.000.
Parameter resets to its default value after power cycling. For example, P3.006.
Description