6.3.4 Scaling of the analog command

In the analog mode, control the motor's Speed command by the analog voltage difference
between V_REF and GND. Use P1.040 and P1.081 (maximum rotation speed for analog Speed
command) to adjust the slope of the speed change and its range. P1.082 can change the filter
switching time between P1.040 and P1.081.
Refer to Chapter 8 for detailed descriptions of the relevant parameters.
Parameter
P1.040
P1.081
P1.082
Speed command
6000 rpm
3000 rpm
-10
-5
3000 rpm
6000 rpm
First set of maximum rotation speed for analog Speed command
Second set of maximum rotation speed for analog Speed command
Filter switching time between P1.040 and P1.081
P1.081 = 6000
P1.040 = 3000
Analog voltage
input (V)
5
10
Function
Operation Mode
6