Overview Of The Pr Procedure - Delta ASDA-B3 Series User Manual

Hide thumbs Also See for ASDA-B3 Series:
Table of Contents

Advertisement

Motion Control

7.1.4 Overview of the PR procedure

In the PR mode, there are six types of commands. To make users understand how the PR
procedure works, ASDA-Soft presents the execution order and calling sequence of all PR
7
procedures. The symbols and contents in the PR diagram are shown as follows. This includes
five parts: number, command execution type (property), command type, next procedure
command, and command information. See Figure 7.1.4.1.
Number: the PR number, ranging from PR#0 to PR#99 (100 sets of PR paths).
(1)
Command execution type (property): (B) execute homing when power on; (O) command
(2)
overlap; (R) write data to EEPROM; (I) command interrupt.
Command type: there are five types of PR procedure commands: homing, speed, position,
(3)
writing, and jumping. The color displayed in this section depends on the command type.
Next procedure command: if followed by a PR command, there would be an arrow pointing
(4)
to the specified PR path.
Command information: displays the details of this PR path. The displayed contents and
(5)
color depend on the information type.
The following sections illustrate each command type and its representation.
7-36
PR#1 (I)(O)
Position
DLY = [0] 0 ms
100000 PUU
INC
200 rpm
Figure 7.1.4.1 Overview of the PR procedure
(1)
(2)
(3)
(4)
(5)
ASDA-B3

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents