6.3.4 The Scaling of Analog Command

The motor speed command is controlled by the analog voltage deviation between V_REF
and VGND. Use parameter P1-40 to adjust the speed-control slope and its range.
Related parameter: Please refer to Chapter 8 for further information.
Parameter
P1-40

6.3.5 The Timing Diagram in Speed Mode

Register
External analog voltage or zero
Exteranl I/O
NOTE
6-20
Abbr.
Function
Maximum Speed of
Analog Speed
VCM
Command
1 ) OFF means the contact point is open while ON means the contact
point is close.
2 ) When it is in Sz mode, the speed command S1 = 0; When it is in S
mode, the speed command S1 is the external analog voltage input.
3 ) When the servo drive is On, please select the command according to
SPD0~SPD1 status.
The slope is determined by P1-40.
Analog Input Voltage (V)
Setting
Set P1-40 to 2000. If the input voltage is
10V, the speed command will be
2000r/min.