Pg-X2 (For Flux Vector Control Mode Only); Pg-X2 Terminal Specifications - YASKAWA VARISPEED-616G5 Instruction Manual

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

Wiring
3.7.2 PG Speed Control Card Terminal Blocks
3

PG-X2 (For Flux Vector Control Mode Only)

J
Table 3.13

PG-X2 Terminal Specifications

Terminal
No.
1
2
3
4
5
TA1
TA1
6
7
8
9
10
1
2
3
TA2
4
5
6
7
TA3
(E)
Note 5 VDC and 12 VDC cannot be used at the same time.
Contents
Power supply for pulse generator
pp y
p
g
A-phase + input terminal
A-phase − input terminal
B-phase + input terminal
B-phase − input terminal
Z-phase + input terminal
Z-phase − input terminal
Common terminal
A-phase + output terminal
A-phase − output terminal
B-phase + output terminal
B-phase − output terminal
Z-phase + output terminal
Z-phase − output terminal
Control circuit common
Shield connection terminal
3 - 26
Specifications
12 VDC (±5%), 200 mA max. (see note)
0 VDC (GND for power supply)
5 VDC (±5%), 200 mA max. (see note)
Line driver input (RS 422 level input)
Line driver input (RS-422 level input)
Maximum response frequency: 300 kHz
0 VDC (GND for power supply)
Line driver output (RS-422 level output)
Line driver output (RS 422 level output)
Control circuit GND

Hide quick links: