Constant Settings; Local/Remote Selection (Setting: 1) - YASKAWA VARISPEED-616G5 Instruction Manual

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

Setting
Setting
value
value
61
External speed search command 1: Maximum output frequency (ON: speed search)
62
External speed search command 2: Set frequency (ON: speed search)
63
Energy-saving command (ON: Energy-saving control set for b8-01, b8-02)
64
External speed search command 3
65
KEB (deceleration at momentary power loss) command (NO contact)
66
KEB (deceleration at momentary power loss) command (NO contact)
71
Speed/torque control change (ON: Torque control)
72
Zero-servo command (ON: Zero-servo)
77
Speed control (ASR) proportional gain switch (ON: C5-03)

Constant Settings

Constant
Number
H1-01
H1-02
H1-03
H1-04
H1-05
H1-06
D
D
3-wire sequence (forward/reverse run command)
Multi-step speed references 1 to 3 and jog fre-
quency reference
Accel/Decel time 1 and 2
Emergency stop
FJOG/RJOG commands
Terminal 13/14 switch
Timer function input
Energy-saving command

Local/Remote Selection (Setting: 1)

D
D
D
Function
Function
Change
User
User
Name
Opera-
Multi-function input
1 (terminal 3)
Multi-function input
2 (terminal 4)
Multi-function input
3 (terminal 5)
Multi-function input
4 (terminal 6)
Multi-function input
5 (terminal 7)
Multi-function input
5 (terminal 8)
The factory settings in parentheses are for when the Unit is initialized for 3-wire control.
The following table shows the settings and section references for some common functions.
Function
OFF
Operate with the frequency reference and run command specified in b1-01 (the frequency refer-
ence source) and b1-02 (run source).
ON
Operate with the frequency reference and run command set at the Digital Operator.
With this setting, the multi-function input selects the input method for the frequency reference and run
command.
The input method can be switched only when the Inverter is stopped.
The Digital Operator LOCAL/REMOTE Key is disabled when this function has been set in a multi-
function input.
7 - 65
g
during
during
Setting
Setting
Unit Factory
Factory
Range
Setting
tion
0 to 77
×
0 to 77
×
0 to 77
3 (0)
×
0 to 77
4 (3)
×
0 to 77
6 (4)
×
0 to 77
8 (6)
×
Setting
0
3 to 6
7, 1A
15
12, 13
1F
18
63
Control Method
V/f
Open
V/f
w/
loop
Vector
PG
×
f
f
×
f
f
×
f
f
f
f
f
f
f
f
f
f
f
×
×
×
×
×
×
×
×
×
Valid Access Levels
Open
V/f
V/f with
Loop
Control
PG
Vector
Vector
24
B
B
B
B
B
B
14
B
B
B
B
B
B
B
B
B
B
B
B
Section
6.1.8
6.1.8
6.1.8
6.1.8
6.1.8
6.1.8
7.5.1
7.2.1, 7.4.1
Flux
vector
×
×
×
f
f
f
f
f
f
Flux
B
B
B
B
B
B
7