The functions that can be used with flux vector control are listed in Table 7.3. Details on functions that are spe-
cific to flux vector control (i.e. those marked with a L) are provided in the following table.
Table 7.3

Flux Vector Control Functions

Function
b1
Sequence
b2
DC Injection Braking
b3
Speed Search
b4
Delay Timers
b5
PID Control
b6
Dwell Functions Hold
b7
Droop Control
b8
Energy Saving
b9
Zero Servo
C1
Accel/Decel
C2
S-Curve Acc/Dec
C3
Motor-Slip Compensation
C4
Torque Compensation
C5
Speed Controls
C6
Carrier Frequency
C7
Hunting Prevention
C8
Factory Tuning
d1
Preset Reference
d2
Reference Limits
d3
Jump Frequencies
Reference frequency hold
d4
function
d5
Torque Control
E1
V/f Pattern
E2
Motor Setup
E3
Motor 2 Control Methods
E4
Motor 2 V/f Characteristics
E5
Motor 2 Motor Constants
PG Speed Control Card
F1
Settings
F2
Analog Reference Card AI
F3
Digital Reference Card DI
F4
Analog Monitor Card AO
F5
Digital Output Card DO
F6
Digital Output Card DO
F7
Pulse Monitor Card PO
SI-F/SI-G Transmission
F8
Card
Transmission Cards other
F9
than SI-K2 and SI-F/G
H1
Multi-function Inputs
H2
Multi-function Outputs
H3
Analog Inputs
Multi-function Analog Out-
H4
puts
MEMOBUS Communica-
H5
tions
Comments
Settings such as the reference input method
DC injection braking function settings
Speed search function settings
Timer function settings
PID control settings
Acceleration/deceleration time dwell function settings
L Droop Control function settings
Not used. (Can't be set.)
L Zero-servo function settings
Acceleration/deceleration time settings
S-curve characteristics for accel/decel times
L Motor temperature compensation function adjustment
Not used. (Can't be set.)
Speed control loop adjustment
Carrier frequency settings
Not used. (Can't be set.)
Not used. (Can't be set.)
Frequency reference settings (when using Operator)
Frequency upper and lower limit settings
Prohibited frequency settings
Up/Down, Accel/Decel stop hold frequency setting
L Torque control settings and adjustment
Motor constant settings
Motor constant settings
L
L
(Motor constants set automatically with autotuning.)
Control method settings for motor 2.
V/f characteristics settings for motor 2.
Motor constant settings for motor 2.
Constant settings for a PG Speed Control Card
User constant settings for an Analog Reference Card
User constant settings for a Digital Reference Card
User constant settings for an Analog Monitor Card
User constant settings for a Digital Output Card
User constant settings for a Digital Output Card
User constant settings for a Pulse Monitor Card
User constant settings for a Transmission Card
User constant settings for a Transmission Card
Function selection for multi-function inputs
Function selection for multi-function outputs
Function selection for analog inputs
Function selection for analog outputs
MEMOBUS communications settings
7 - 16
Control Meth-
od
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
×
×
×
f
×
×
f
f
×
×
×
f
f
f
f
f
f
f
f
f
f
f
f
f
×
f
f
f
×
×
f
f
f
f
f
f
×
×
f
f
×
×
×
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
×
×
×
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
×
×
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f
f

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents