Initialize Mode Constants - YASKAWA VARISPEED-616G5 Instruction Manual

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

8.1 Initialize Mode Constants

Name
C
Constant
Number
Display
Language selection
for digital operator
display
A1-00
Select Language
Constant access level
A1-01
A1 01
Access Level
User setting constant
A1 02
A1-02
User Param 1 to 32
Initialize
A1-03
A1 03
Init Constants
Password 1
A1-04
A1 04
Enter Password
Password 2
A1 05
A1-05
Select Password
Description
Used to select the language dis-
played on the Digital Operator
0: English
1: Japanese
2: German
3: French
4: Italian
5: Spanish
6: Portuguese
:This constant is not initialized
by the initialize operation.
Used to set the constant access
level (set/read.)
0: Monitoring only (Displays
only Operation mode and Ini-
tialize mode)
1: Used to select user constant
1: Used to select user constant
(Constants A2-01 to A2-32
only can be set/read.)
2: Quick-Start : Q
3: Basic : B
4: Basic : A
Used to select the control method
for the Inverter
0: V/f control
1: V/f with PG feedback
V/
G
2: Open loop vector
3: Flux vector
:This constant is not initialized
by the initialize operation.
Used to initialize the constants us-
ing the specified method.
0: No initializing
1110: Initializes using the User
constants
constants
2220: Initializes using a two-wire
sequence. (Initializes to the
factory setting.)
3330: Initializes using a three-wire
sequence.
Password input when a password
has been set in A1-05. This func-
tion write-protects some constants
of the Initialize mode.
:If the password is changed,
:If the password is changed,
A1-01 to A1-03 and A2-01 to
A2-32 constants can no longer
be changed. (Programming
mode constants can be
changed.)
Used to set a four digit number as
the password.
:This constant is not usually dis-
played. When the password
played. When the password
(A1-04) is displayed, hold
down the Reset/Select Key and
press the Menu Key and the
password will be displayed.
8 - 3
Change
Change
S
Setting
Factory
during
Opera-
Range
Setting
V/f
tion
0, 1
1
Q
f
0 to 4
0 to 4
2
2
Q
Q
f
f
0 to 3
0 to 3
2
2
Q
Q
×
×
0 to
0 to
Q
Q
0
0
×
×
3330
0 to
0 to
0
0
Q
Q
×
×
9999
0 to
0 to
0
0
Q
Q
×
×
9999
8.1 Initialize Mode Constants
Control Methods
V/f
Page
Open
Flux
with
Loop
Vector
Vector
PG
Q
Q
Q
4 - 19
Q
Q
Q
Q
Q
Q
4 - 19
4 19
Q
Q
Q
Q
Q
Q
4 20
4 - 20
Q
Q
Q
Q
Q
Q
4 21
4 - 21
Q
Q
Q
Q
Q
Q
4 - 23
4 23
Q
Q
Q
Q
Q
Q
4 - 23
4 23
8

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents