Failure To Observe This Caution May Result In Motor Malfunctions Such As Sudden Acceleration; S In The Following Cases When Under Flux Vector Control, Be Sure To Adjust The Pg Zero-Pulse As Described In 4.3 (3) (E) Pg Zero-Pulse Adjustment; Before Initial Operation; After Replacing The Motor - YASKAWA CIMR-SSA Series Instruction Manual

Table of Contents

Advertisement

Set the motor constants in accordance with the values listed on the motor nameplate.
If the open loop vector control is selected, set
the motor constants in the order shown in
Table 11.
If the flux vector control is selected, set the
motor constants in the order shown in Table
12.
If the setting of the motor capacity selection
(E1-02) is changed, the motor constants will
return to their initial values.
Constant
Name
No.
A1-01
Constant access level
A1-02
Control method selection
E1-02
Motor capacity selection
E1-03
Motor rated voltage
E1-04
Motor rated current
E1-05
Number of motor poles
E1-06
Motor max. speed
E1-07
Motor base speed
E1-08
Motor min. speed
E1-09
Motor armature resistance
E1-10
Motor d-axis inductance
44
(b) Setting Motor Constants
S Be sure to set the motor constants before the initial operation and after replacement of the
motor. Reconfirm the motor constants after they have been set.

Failure to observe this caution may result in motor malfunctions such as sudden acceleration.

S In the following cases when under flux vector control, be sure to adjust the PG zero-pulse
as described in 4.3 (3) (e) PG Zero-pulse Adjustment:

• Before initial operation.

• After replacing the motor.

• After replacing the PG.

Table 11
Motor Constants Setup for Open Loop Vector Control
Set Value
(On Nameplate)
4
5
See remarks.
(V)
(A)
(POLES)
(r/min) or (min
(r/min) or (min
10% of the base
speed or higher
(R1)
(Ld)
CAUTION
Main Nameplate
VARISPEED-686SS5
3-PHASE PERMANENT MAGNET MOTOR
TYPE
PROTECTION
kW
V
E1-03
E1-03
INS.
COOLANT TEMP.
STD
BRG NO
SER NO
YASKAWA ELECTRIC CORPORATION
Fig. 20 Example of Motor Nameplate
5: Open loop vector control
Refer to Table A-6 Motor Capacity Selection List in Appendix
4.
If two values for (V) are shown on the nameplate, set E1-03 to
the value in the lower row.
If two values for (A) are shown on the nameplate, set E1-04 to
the value in the lower row.
If (POLES) is not shown on the nameplate, set E1-05 to 6.
-1
)
If two values are shown for (r/min) or (min
value in the upper row.
-1
)
If two values are shown for (r/min) or (min
value in the lower row.
Initial setting: 10% of base speed.
POLES
E1-05
COOLING
Hz
RATING
A
r/min
E1-04
E1-06, 07
E1-04
E1-07
ALTITUDE
_C
MASS
kg
YEAR
JAPAN
Remarks
-1
), set E1-06 to the
-1
), set E1-07 to the
PARAMETER
R
E1-09
1
Ld
E1-10
Lq
E1-11
E1-13
Ke
C2-12, 13
Ki
C3-02
Kt
m
C3-03
Si
B3-03
Checked