Setting The Pg Pulse Number: F1-01; Setting The Number Of Pg Gear Teeth: F1-12, F1-13; Selecting Integral Operation During Acceleration/Deceleration: F1-07; Setting And Adjusting The Fault Detection Functions - YASKAWA VARISPEED-616G5 Instruction Manual

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

Basic Operation
6.5.3 PG Speed Control Card Settings
6.5.3 PG Speed Control Card Settings
6
Available PG Speed Control Cards
J
There are 4 models of PG Speed Control Cards, but only 2 models can be used with vector control.
D
PG-A2: Phase-A/Phase-B pulse inputs, complementary output
PG-D2: Phase-A/Phase-B/Phase-Z pulse inputs, line drivers
Select the Card according to the application and install it in the Inverter as described in 3.7 Installing
D
and Wiring PG Speed Control Cards.

Setting the PG Pulse Number: F1-01

J
Set the PG (pulse generator or encoder) pulse number in pulses/revolution.
D
Set the number of phase A or phase B pulses in one motor revolution.
D
User
User
Constant
Name
Number
F1-01
PG constant

Setting the Number of PG Gear Teeth: F1-12, F1-13

J
When "V/f control with PG feedback" is used, the motor can be operated even if there are gears be-
D
tween the motor and PG because the responsiveness is lower than it is with vector control.
Set the number of teeth on the gears if there are gears between the motor and PG.
D
The motor speed will be calculated within the Inverter using the following equation:
D
Motor speed (r∕min) =
User
User
Constant
Name
Number
Number of PG gear
F1-12
teeth 1
Number of PG gear
F1-13
teeth 2
A gear ratio of 1 (F1-12 = F1-13 = 1) will be used if either of these constants is set to 0.
D

Selecting Integral Operation During Acceleration/Deceleration: F1-07

J
When "V/f control with PG feedback" is used, integral control during acceleration and deceleration
D
can be enabled or disabled with F1-07.
Set F1-07 to "1" (integral control enabled) if you want to keep the motor speed as close to the frequency
D
reference as possible during acceleration and deceleration. Set F1-07 to "0" (integral control disabled)
if you want to prevent the occurrence of overshooting/undershooting.
User
User
Constant
Name
Number
Integral value during
F1-07
accel/decel enable/
disable
Settings
D
Setting
0
Disabled (The integral function isn't used while accelerating or decelerating; it is used at
constant speeds.)
1
Enabled (The integral function is used at all times.)

Setting and Adjusting the Fault Detection Functions

J
PG Disconnection Stopping Method: F1-02, F1-14
This constant sets the stopping method that is used when the signal from the PG is lost.
D
Change
g
during
during
Setting
Setting
Opera-
Range
tion
0 to 60000
×
Number of pulses input from the PG × 60
Number of PG pulses (F1−01)
Change
g
during
during
Setting
Setting
Opera-
Range
tion
0 to 1000
×
0 to 1000
×
Change
g
during
during
Setting
Setting
Opera-
Range
tion
0, 1
×
6 - 42
Valid Access Levels
Unit Factory
Factory
V/f
V/f with
Setting
Control
PG
p/r
600
Q
×
Number of gear teeth 2 (F1−13)
×
Number of gear teeth 1 (F1−12)
Valid Access Levels
Unit Factory
Factory
V/f
V/f with
Setting
Control
PG
A
0
×
0
A
×
Valid Access Levels
Unit Factory
Factory
V/f
V/f with
Setting
Control
PG
B
0
×
Function
Open
Flux
Loop
Vector
Vector
Q
×
Open
Flux
Loop
Vector
Vector
×
×
×
×
Open
Flux
Loop
Vector
Vector
×
×