3-Wire Sequence (Forward/Reverse Run Commands): “0”; 3-Wire Sequence Wiring Example; Multi-Step Speed References 1 Through 3 / Jog Reference; Timing Chart For 3-Wire Sequence - YASKAWA VARISPEED-616G5 Instruction Manual

200v class 0.4 to 75kw (1.2 to 110kva) 400v class 0.4 to 300kw (1.4 to 460kva)
Hide thumbs Also See for VARISPEED-616G5:
Table of Contents

Advertisement

Basic Operation
6.1.8 Multi-function Input Settings: H1-01 through H1-06
6
3-wire Sequence (Forward/Reverse Run Commands): "0"
J
When a value of "0" is set for any one of the multi-function inputs (H1-01 through H1-06), 3-wire se-
D
quence control is used and the multi-function input terminal for which "0" was set becomes the for-
ward/reverse run command terminal.
When the Unit is initialized for 3-wire sequence control with A1-03 , multi-function input 3 (terminal
D
5) becomes the input terminal for the forward/reverse run command.
Stop switch (NC) Run switch (NO)
Fig 6.8

3-wire Sequence Wiring Example

Run command
Stop command
Forward/reverse run
command
Motor speed
Fig 6.9

Timing Chart for 3-wire Sequence

Multi-step Speed References 1 through 3 and JOG Reference: "3" to "6"
J
Eight frequency references and one jog frequency reference can be used.
D
Set the multi-step speed references 1, 2, and 3 and the JOG reference for the multi-function inputs, and
D
change the status of these inputs to switch between the 9 frequency references.
Terminal
Constant
5
H1-03
6
H1-04
7
HI-05
8
H1-06
1
Run command
(Operates when the run switch is closed.)
2
Stop command
(Stops when the stop switch is open.)
5
Forward/reverse command
(Multi-function input)
11
Sequential input common
50 ms min.
ON/OFF (Either is possible.)
OFF (Forward)
ON (Reverse)
Stop
Forward
Setting
Multi-step speed reference 1 (Also used for master-speed/auxiliary-speed
3
switching when an auxiliary reference is set for the multi-function analog
input in H3-05.)
4
Multi-step speed reference 2
5
Multi-step speed reference 3
JOG reference (This setting has higher priority than the multi-step speed
6
reference.)
6 - 14
OFF (Stop)
Reverse
Stop
Forward
Function