User Constants Settable In Quick Programming Mode - YASKAWA Varispeed CIMR-G7A Instruction Manual

General purpose inverter (advanced vector control) 200v/400v class 0.4 to 110/300 kw (1.2 to 160kva) (1.04 to 460kva)
Hide thumbs Also See for Varispeed CIMR-G7A:
Table of Contents

Advertisement

User Constants Settable in Quick Programming Mode

The minimum user constants required for Inverter operation can be monitored and set in quick programming
mode. The user constants displayed in quick programming mode are listed in the following table. These, and
all other user constants, are also displayed in advanced programming mode.
Refer to the overview of modes on page 3-4 for an overview of quick programming mode.
Con-
stant
Number
Control
method
selection
A1-02
Control
Method
Reference
selection
b1-01
Reference
Source
Operation
method
selection
b1-02
Source
Stopping
method
selection
b1-03
Stopping
Method
Accelera-
tion time 1 Set the acceleration time in seconds
C1-01
Accel
Time 1
Decelera-
tion time 1 Set the deceleration time in seconds
C1-02
Time 1
Carrier fre-
quency
selection
C6-02
Carrier
Freq Sel
-4
5
Name
Description
Display
Set the control method for the Inverter.
0: V/f control
1: V/f control with PG
2: Open-loop vector 1 control
3: Flux vector control
4: Open-loop vector 2 control
Set the frequency reference input
method.
0: Digital Operator
1: Control circuit terminal (analog
input)
2: MEMOBUS communications
3: Option board
4: Pulse train input
Set the Run Command input method
0: Digital Operator
1: Control circuit terminal (sequence
input)
Run
2: MEMOBUS communications
3: Option board
Select stopping method when Stop
Command is sent.
0: Deceleration to stop
1: Coast to stop
2: DC braking stop (Stops faster than
coast to stop, without regenerative
operation.)
3: Coast to stop with timer (Run
Commands are disregarded during
deceleration time.)
for the output frequency to climb from
0% to 100%.
for the output frequency to fall from
Decel
100% to 0%.
Select carrier wave fixed pattern.
Select F to enable detailed settings
using constants C6-03 to C6-07.
Change
Setting
Factory
during
Range
Setting
Opera-
V/f
tion
0 to 4
2
No
Q
0 to 4
1
No
Q
0 to 3
1
No
Q
0 to 3
0
No
Q
*11
Yes
Q
0.0 to
10.0 s
6000.0
*1
Yes
Q
1 to F
6
No
Q
*12
*2
Control Methods
MEMO
Open
Open
BUS
V/f
-loop
Flux
Loop
Regis-
with
Vec-
Vec-
Vec-
ter
PG
tor
tor
tor
1
2
Q
Q
Q
Q
102H
Q
Q
Q
Q
180H
Q
Q
Q
Q
181H
Q
Q
Q
Q
182H
Q
Q
Q
Q
200H
Q
Q
Q
Q
201H
No
Q
Q
Q
224H
*13