• Frequency Reference by Pulse Train Input

Frequency reference can be set by pulse train input from the multi-function input
terminal.
• Input pulse specifications
• Low-level voltage: 0.8V or less
• High-level voltage: 3.5 to 32V
• Duty Cycle: 30 to 70%
• Pulse frequency: 0 to 33 kHz
• Frequency reference method
Frequency reference is a value obtained by multiplying the ratio of the maximum
input pulse frequency and actual input pulse frequency by the maximum output
frequency.
Reference freq
Parameter
No.
n003
n004
Frequency reference selection
n149
Pulse train input scaling 1=10Hz
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com
Input pulse frequency
=
-----------------------------------------------------------------------------------------------------------------
×
Minimum pulse train frequency (n149) 10
Run/stop and FWD/REV can
be selected by a switch
connected to the control circuit
terminal.
Frequency setting can be set
by pulse train input signal [0 to
100% (maximum frequency)/0
to 33kHz] connected to the
multi-function input terminal.
Name
Unit
Setting range
Run command selection
1
0 to 2
1
0 to 6
100 to 3300
1
(33kHz)
×
max output frequency (n011)
Initial Setting
0
0
2500
(25kHz)