Installing The Ne Software - Lucent Technologies LambdaUnite MSS Installation Manual

Multiservice switch
Table of Contents

Advertisement

Installing the NE software

....................................................................................................................................................................................................................................
Overview
Before you begin
Software installation
....................................................................................................................................................................................................................................
B - 2
The software generic has to be copied from the CD-ROM (Comcode
109088708) to the WaveStar
CompactFlash
CompactFlash card is inserted into the NE.
Prior to performing this task, you must
1.
have 120 MB of free hard-disk drive space.
2.
have a valid login on both the WaveStar CIT and the NE.
3.
acquire the CD-ROM that contains the generic/version of the NE
software (Comcode 109088708).
Required privilege code
You must have at least a privilege code of S4.
Required equipment
The following equipment is required to perform this task:
Empty 256 MB CompactFlash card (as delivered from
manufacturer)
CD-ROM that contains the generic/version of the NE software
PC with CompactFlash or PCMCIA slot. For the second case an
adapter is required.
To reload the NE software proceed as follows:
............................................................................................................................................................
Power up the WaveStar CIT PC and log into Windows® NT /
1
Windows® 2000 as administrator. If you are already logged into
Windows® NT / Windows® 2000, close any open window.
............................................................................................................................................................
Install the NE software onto your PC. To do this, use one of the
2
following two methods (automatic or manual installation):
Lucent Technologies
®
CIT PC and then to an empty
card via WaveStar CIT. Afterwards, the
NE software installation
365-374-074
Issue a, April 2002