Connecting The Fiber Cables - Lucent Technologies LambdaUnite MSS Installation Manual

Multiservice switch
Table of Contents

Advertisement

Network establishment

Connecting the fiber cables

....................................................................................................................................................................................................................................
Background information
Before you begin
Procedure
....................................................................................................................................................................................................................................
8 - 6
The LC attenuator which will be determined in the procedure
described below should be placed on the INPUT port because this is
the furthest physical point on the fiber line from the OUTPUT port
and takes all connector losses into account.
Be sure that all fiber connectors are clean. A cleaning procedure is
described in Appendix A, section
DANGER
Injury to eyes caused by invisible laser radiation.
LambdaUnite
radiation. Laser radiation can cause considerable injuries to
the eyes.
Never look into the end of an exposed fiber or into an
open optical connector as long as the optical source is
switched on. Always observe the laser warning
instructions (cf.
Proceed as follows to establish a network:
............................................................................................................................................................
Connect an optical fiber to the OUT port of one optical circuit pack.
1
............................................................................................................................................................
Move to the next NE. At the IN port of the respective optical circuit
2
pack measure the received optical power from the far-end transmitter.
Important! The optical power meter must be set to the appropriate
wavelength range.
..........................................................................................................................................................
Check that the measured value is within the range shown below (see
3
section
"Optical power and wavelength ranges"
Lucent Technologies
"Fiber cleaning"
MSS systems operate with invisible laser
"Laser safety"
(1-11)).
Span / Ring testing
(A-13).
(8-8)).
365-374-074