DWDM mounting

....................................................................................................................................................................................................................................
Before you begin
Installation procedure
....................................................................................................................................................................................................................................
D - 4
Check the materials before installation.
............................................................................................................................................................
1
Mount the 19"or 23" mounting bracket (item 2) on the Shell Holder
(item 1) as shown in the next figure. The type of rack frame defines
whether a 19"or 23" mounting bracket is used.
............................................................................................................................................................
Mount the Guide Bracket — DC1005064 (item 6) with the assembled
2
Shell Holder on the rack frame using the Screw, Tapping
Thread-Forming, M6x16 — CC901331421.
............................................................................................................................................................
Click the Fiber-Routing Guides (corner) — DC1001518 (item 7) to
3
Guide Bracket — DC1005064 (item 6) as shown in the next figure for
both configurations.
..........................................................................................................................................................
If applicable, connect the grounding cables from the Shell Holder at
4
the rear side with Screw, Tapping Thread-Forming, M6x16 —
CC901331421 to the grounding point of the rack frame.
IF the Passive DWDM is
positioned
above the the middle of
the rack (Upper part).
below the the middle of
the rack (Bottom part).
............................................................................................................................................................
Open the Shell Holder Unit by pushing simultaneously at both sides
5
the buttons on the front door.
............................................................................................................................................................
6
Slide the passive DWDM (item 3) into the Shell Holder until the
PWDM locks. It can be released by pushing the buttons on each side
simultaneously.
Lucent Technologies
Passive DWDM (OEM equipment)
THEN .......
use the ground wire (2000 mm [6,562
ft]) — CC848828174
use the ground wire (3000 mm [9,843
ft]) — CC848828182
365-374-074