Internal cable installation

Station alarm interface

....................................................................................................................................................................................................................................
Station alarms
Cable data
Connector data
....................................................................................................................................................................................................................................
4 - 2 6
This interface consists of 6 isolated output-pairs. The ports can switch
both 0.5A at 72V and 2.0A at 30V. Critical contacts (visual and
acoustic) can be configured to be active without system power. These
contacts are closed if there is loss of control or of power.
Length of pre-fabricated cables, 8 x 2 x 0.4 mm / AWG26 + overall
screen:
10 m [32.808 ft] Cable Assy, Station Alarm — CC109155788
25 m [82.021 ft] Cable Assy, Station Alarm — CC109155796
50 m [164.042 ft] Cable Assy, Station Alarm — CC109155804
75 m [246.063 ft] Cable Assy, Station Alarm — CC109164186
100 m [328.084 ft] Cable Assy, Station Alarm — CC109164194
Type of Connector
Code no. of Connector
Code no. of Hood
Lucent Technologies
System cabling and final assembly
D-SUB pin, 25p solder
CC407362730
DC1003599
365-374-074
Issue a, April 2002