Remote Login Failure - Lucent Technologies LambdaUnite MSS Installation Manual

Multiservice switch
Table of Contents

Advertisement

Remote login failure

....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
The procedure described below should be performed if no remote
login is possible (see Chapter 8, section
Follow the steps below in the case of a remote login failure:
............................................................................................................................................................
Check that the DCC channels are configured correctly (see Chapter 8,
1
section
"Provision DCC"
IF ...
a remote login is not
possible,
a remote login is possible,
..........................................................................................................................................................
Reset the CTL circuit pack of the near-end NE. To do this, open the
2
latches simultaneously and wait until the red LED is illuminating
continously. Then pull and move back the controller.
IF ...
a remote login is not
possible,
a remote login is possible,
..........................................................................................................................................................
Reset the CTL circuit pack of the far-end NE.
3
IF ...
a remote login is not
possible,
a remote login is possible,
..........................................................................................................................................................
Perform a reload of the NE software to the CompactFlash card of the
4
near-end NE (see
Lucent Technologies
(8-10)).
THEN ...
proceed to step 2.
END OF STEPS
THEN ...
proceed to step 3.
END OF STEPS
THEN ...
proceed to step 4.
END OF STEPS
Appendix B, "NE software
Installation trouble shooting
"Remote login"
(8-12)).
installation").
A - 9