Alarm reporting test

....................................................................................................................................................................................................................................
Overview
Related information
Procedure
....................................................................................................................................................................................................................................
7 - 4
This test verifies that currently active alarms of the system are
reported to the WaveStar
raise and clear behaviour of the alarms created.
All the needed information for the tasks described below (creating and
clearing of alarms) is given in the " LambdaUnite
Switch (MSS) User Operations Guide".
Proceed as follows to complete the alarm test:
............................................................................................................................................................
Login to the NE as described in Chapter 6, section
1
procedure"
(6-12).
............................................................................................................................................................
Create the different alarms in sequence as shown in the table below.
2
Example:
Create the following alarms separately:
Created alarm
Protection
Clock Input
Fail
NE Clock
Failure
Lucent Technologies
®
CIT and the user panel. The test includes
Alarm level
Example for creation of
the alarm
Deferred/
Remove the XC320 circuit
Minor
pack which is located in the
protection slot 10.
Prompt/
Remove both XC320 circuit
Critical
packs (worker and
protection).
Stand alone test procedures
MultiService
"NE login
365-374-074
Issue a, April 2002