SONET test procedures

Provision DCC

....................................................................................................................................................................................................................................
Purpose
Before you begin
Max. number of active DCC
Procedure
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
Use this procedure to create new DCC (Data Communication
Channel) terminations. They are necessary for exchanging network
management information between NEs and performing the tests
described in this chapter.
Important! Only ports to which fiber cables are connected should be
configured for DCC terminations!
Prior performing this task,
you must have at least a privilege code of S4
a XC320 circuit pack must be plugged.
The maximum number of simultaneously supported DCC channels per
links
DCC controller is 64. That means, each DCC controller can support
up to 64 active DCC links.
Proceed as follows to create a new DCC termination:
............................................................................................................................................................
Login to the NE as described in Chapter 6, section
1
procedure"
(6-12).
............................................................................................................................................................
Invoke the
2
Configure DCC Terminations
View
main menu via
............................................................................................................................................................
3
Select the circuit pack for which you want to configure the DCC
terminations and click
............................................................................................................................................................
Select
New Termination
4
............................................................................................................................................................
Click on
5
Select port for new DCC termination...
optical interface port for which you want to configure the DCC
terminations.
Lucent Technologies
Configuration
DCC Terminations...
.
Select
in the parameter part (tab
Span / Ring testing
"NE login
window from the
System
Section DCC
and select the
).
8 - 2 9