Remote Login - Lucent Technologies LambdaUnite MSS Installation Manual

Multiservice switch
Table of Contents

Advertisement

SONET test procedures

Remote login

....................................................................................................................................................................................................................................
Overview
Before you begin
Test setup
Procedure
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
The test ensures the accessibility to all NEs via remote login. In the
test procedure a protected ring configuration will be used as example.
However, the described procedure is in principle also valid for other
network topologies.
This test can only be done after the DCC channels have been
configured correctly (see section
East
NE-D
West
Proceed as follows to test the NE control and supervision
functionality via remote login:
............................................................................................................................................................
Login to the NE-A as described in Chapter 6, section
1
procedure"
(6-12).
Lucent Technologies
"Provision DCC"
NE-C
Port 1
Port 1
West
East
Out
In
Port 1
Port 1
In
Out
®
WaveStar CIT
NE-A
Port 1
Port 1
East
West
Out
In
Port 1
Port 1
In
Out
Span / Ring testing
(8-29)).
West
NE-B
East
"NE login