Fan Unit Test - Lucent Technologies LambdaUnite MSS Installation Manual

Multiservice switch
Table of Contents

Advertisement

Power initialisation

Fan unit test

....................................................................................................................................................................................................................................
Overview
Procedure
....................................................................................................................................................................................................................................
365-374-074
Issue a, April 2002
This test clarifies the correct working of the fan unit in the
LambdaUnite
MultiService Switch (MSS) subrack. The test should
be carried out for each installed NE.
Proceed as follows to test the correct functionality of the fan
unit:
............................................................................................................................................................
Control the status indication on the faceplate of the fan unit.
1
Result:
On the fan unit only the PWR ON LED should be lit.
............................................................................................................................................................
2
Check that
all fans of the unit are running
the air flow direction is from bottom to top.
E
S
N D
O F
T E P S
.........................................................................................................................................................................................................................................................
Lucent Technologies
Powering, circuit pack installation, and NE software
download
5 - 7