Dc Power Cable Specifications; Mx104 Power Consumption; Power Requirements For Mx104 Components; Table 27: Power Consumed By Mx104 Routers - Juniper MX104 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX104:
Table of Contents

Advertisement

MX104 3D Universal Edge Router Hardware Guide

DC Power Cable Specifications

Related
Documentation

MX104 Power Consumption

Related
Documentation

Power Requirements for MX104 Components

164
You must supply two DC power cables for each DC power supply that meet the following
specifications: 14-AWG (2.08 mm
code.
Connecting DC Power Cables to the MX104 Router on page 54
Replacing an MX104 DC Power Supply on page 98
MX104 DC Power Electrical Safety Guidelines on page 142
DC Power Electrical Safety Warnings for Juniper Networks Devices on page 143
MX104 DC Power Specifications on page 162
The MX104 router supports installation of up to two AC or DC power supplies in slots
labeled on the front of the router.
Table 27 on page 164
lists the power consumed by the MX104 router.
NOTE:
The power consumption values are measured from the power source
and are based on systems that contain redundant power supplies, redundant
Routing Engines, a fan tray, and are fully loaded with MICs.

Table 27: Power Consumed by MX104 Routers

Description
Power consumed by the AC router (typical)
Power consumed by the DC router (typical)
Power consumed by the AC router without MICs (typical)
Power consumed by the DC router without MICs (typical)
Connecting DC Power Cables to the MX104 Router on page 54
MX104 DC Power Electrical Safety Guidelines on page 142
MX104 DC Power Specifications on page 162
Table 28 on page 165
lists the power requirements for Field Replaceable Units (FRUs)
that install into MX104 routers.
2
), minimum 90° C wire, or as required by the local
Copyright © 2014, Juniper Networks, Inc.
Value
600 W
625 W
325 W
350 W