Figure 15: Grounding Points On The Mx104 Router - Juniper MX104 Hardware Manual

3d universal edge router
Hide thumbs Also See for MX104:
Table of Contents

Advertisement

MX104 3D Universal Edge Router Hardware Guide
Related
Documentation
52
Secure the grounding cable lug with the washers and screws. The holes are sized for
8.
SAE 10-32 screws. Apply 4.34 lb-in. (0.49 Nm) of torque to each screw. Do not
overtighten the screw. (Use a number 2 Phillips screwdriver.)
CAUTION:
Ensure that each grounding cable lug seats flush against the
surface of the grounding points as you are tightening the screws. Ensure
that each screw is properly threaded into the grounding points. Applying
installation torque to the screw when it is improperly threaded may
damage the terminal.
CAUTION:
The maximum torque rating of the grounding screws on the
router is 4.34 lb-in. (0.49 Nm). The grounding screws may be damaged if
excessive torque is applied. Use only a torque-controlled driver to tighten
screws. Use an appropriately sized driver, with a maximum torque capacity
of 5 lb-in. or less. Ensure that the driver is undamaged and properly
calibrated and that you have been trained in its use. You may wish to use
a driver that is designed to prevent overtorque when the preset torque
level is achieved.
Dress the grounding cable, and verify that it does not touch or block access to router
9.
components, and that it does not drape where people could trip on it.

Figure 15: Grounding Points on the MX104 Router

1—
Grounding cable lug
Installing and Connecting an MX104 Router Overview on page 43
Connecting AC Power Cords to the MX104 Router on page 53
2—
Screws
Copyright © 2014, Juniper Networks, Inc.