Carrying Out An Acceptance Test (Example) - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Safety Integrated Basic Functions
11.11 Acceptance test and acceptance report
3. In the secondary navigation for the desired drive, select all Safety Integrated Functions
being tested.
The active functions are automatically pre-selected. You can change this pre-selection and
select/deselect functions.
4. In order to define the function selection for the Safety Integrated acceptance test, click on
"Accept."
For the functions being tested, entries are shown in the secondary navigation. Navigate with
these settings to the individual tests.
Resetting test results
1. In order to delete all tests previously carried out for this drive, click on the "Reset test results"
button.
This restores the initial state, which can be used to carry out the acceptance test again. A
confirmation prompt is displayed.
2. Acknowledge the query with "Yes".
Then the results are reset and you can restart the acceptance test using new settings as
needed.
11.11.3.2

Carrying out an acceptance test (example)

After accepting the function selection in the Preparing the acceptance test (Page 685) step,
Startdrive shows the functions being tested in the secondary navigation.
You can now work through the tests in any order.
The status of the individual tests is represented as follows:
● Blue: The test is initial and has not yet been started.
● Green: The test was performed successfully.
● Red: The test was aborted with error. The test can be repeated by reselecting the function.
Structure of the acceptance test wizards
The listed wizards have the same structure for every acceptance test.
In the upper area, the workflow represents the individual test steps and their status. The
statuses have the following meaning:
● Blue: Active test step.
● Green: Test step completed.
In the area below the workflow, Startdrive displays the instructions for the test steps. You must
carry out these test steps. Once you have carried out the instructions, click "Next" to go to the
next step. Finally, close the text by clicking on "Finish." Then Startdrive updates the status for
this test in the secondary navigation.
The operator controls for the test steps are located in the lower area. These controls include,
for example, the control panel for moving the axis being tested.
686
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Drive functions

Advertisement

Table of Contents
loading

Table of Contents