In the DP cycle, all time stamps for rising and falling edges are transferred corresponding to
their sequence in time for probe 1.
Example 3
MT_STW = 303H: a search is made for rising and falling edges for probes 1 and 2.
Figure 5-33
In the DP cycle, initially all time stamps for rising and falling edges of probe 1 are entered.
Afterwards, all time stamps for rising and falling edges of probe 2.
5.22.2

Function diagrams and parameters

Function diagrams (see SINAMICS S120/S150 List Manual)
● 2423
● 4740
Overview of important parameters (see SINAMICS S120/S150 List Manual)
● r0565[0...15]
● r0566[0...3]
● r0567
● p0680[0...7]
● p0681
● p0682
● p0684
● r0685
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
A search is made for rising and falling edges for probes 1 and 2
PROFIdrive - Manufacturer-specific/free telegrams and process data
Encoder evaluation - Probe evaluation, measured value memory, encoders 1 ...
3
CO: Probe time stamp
CO: Probe time stamp reference
CO: Probe diagnostic word
Central probe, input terminal
BI: Central probe synchronization signal, signal source
CI: Central probe control word signal source
Central probe evaluation procedure
Central probe control word display
Servo control
5.22 Central probe evaluation