Procedure
1. Click in the "Drive objects and components" display area on the "Components" tab.
Then, the information and messages regarding the components are displayed in a list.
Figure 13-18
2. In order to carry out an LED flash test for individual components, click on
corresponding line.
The ready LED on the corresponding component then begins to flash.
3. If needed, you can re-sort the individual columns by clicking on the corresponding column
head (e.g. Type).
You can view the entries in ascending
Note
Re-sorting the entries in a list affects only the list currently being shown. Re-sorting has no
effect on other lists.
A red or orange marking indicates a DRIVE-CLiQ wiring error on a component. Switch to the
"Topology" tab in order to view further information.
Displaying DRIVE-CLiQ wiring errors
In order to view existing DRIVE-CLiQ wiring errors and diagnostic information about the
individual components of your drive, proceed as follows:
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Example: "Components" display area
13.3 Diagnostic functions
or descending