Servo control

5.19 Travel to fixed stop

5.19
Travel to fixed stop
Function description
This function can be used to move a motor to a fixed stop at a specified torque without a fault
being signaled. When the stop is reached, the specified torque is established and is then
continuously available.
The desired torque derating is brought about by scaling the upper/motor-mode torque limit and
the lower/regenerative-mode torque limit.
Applications
The main applications of the function are:
● Screwing parts together with a defined torque
● Moving to a mechanical reference point
Signals
For PROFIdrive telegrams 2 to 6, the following signals are automatically interconnected:
● Control word 2, bit 8 (STW2.8)
● Status word 2, bit 8 (ZSW2.8)
For PROFIdrive telegrams 102 to 106, the following signals are also interconnected:
● Message word, bit 1 (MELDW1)
● Process data M_red to the scaling of the torque limit
When the "basic positioner" function module is activated, the signals listed above are
automatically interconnected to the basic positioner.
176
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Drive functions