Basic information about the drive system
14.8 Know-how protection
Figure 14-21
The active input fields are mandatory inputs.
3. Enter the required password in the "New password" field and enter it again in the "Confirm
password" field.
4. If the associated input fields are active, enter the serial numbers:
– The serial number of the new memory card for which the data is intended
– The serial number of the Control Unit
5. If, despite active know-how protection, you permit diagnostic functions, activate the "Allow
diagnostic functions (trace and measuring function)" option with a mouse click.
This allows the trace function, the measuring function and the function generator to be used
despite know-how protection.
6. Click "OK" to confirm the settings you made.
Result
The activation of the know-how protection starts the encryption of the subproject data. If larger
data volumes are being encrypted, a progress display informs that the encryption or the
activation of the know-how protection is still running. With the aid of this encrypted data, an end
user can install a new memory card for the drive unit.
14.8.5

Overview of important parameters

Overview of important parameters (see SINAMICS S120/S150 List Manual)
● r7758[0...19]
● p7759[0...19]
● r7760
● p7763
● p7764[0...n]
820
Activating load to file system know-how protection
KHP Control Unit serial number
KHP Control Unit reference serial number
Write protection / know-how protection status
KHP OEM exception list number of indices for p7764
KHP OEM exception list
Function Manual, 06/2019, 6SL3097-5AB00-0BP2