Overview Of Important Parameters - Siemens SINAMICS S120 Function Manual

Hide thumbs Also See for SINAMICS S120:
Table of Contents

Advertisement

Basic functions
8.21 Tolerant encoder monitoring
8.21.15

Overview of important parameters

Overview of important parameters (see SINAMICS S120/S150 List Manual)
● p0404[0...n]
● p0405[0...n]
● p0408[0...n]
● p0430[0...n]
● p0437[0...n]
● p0438[0...n]
● r0452[0...2]
● r0458[0...2]
● r0459[0...2]
● p4680[0...n]
● p4681[0...n]
● p4682[0...n]
● p4683[0...n]
● p4684[0...n]
● p4686[0...n]
● r4688[0...2]
● r4689[0...2]
384
Encoder configuration active
Square-wave encoder track A/B / square-wave encoder A/B
Rotary encoder pulse No.
Sensor Module configuration
Sensor Module extended configuration
Square-wave encoder filter time
Square-wave encoder filter time display
Sensor Module properties
Sensor Module extended properties
Zero mark monitoring tolerance permissible
Zero mark monitoring tolerance window limit 1 positive
Zero mark monitoring tolerance window limit 1 negative
Zero mark monitoring tolerance window alarm threshold positive
Zero mark monitoring tolerance window alarm threshold negative
Zero mark, minimum length
CO: Zero mark monitoring, number of differential pulses
CO: Square-wave encoder diagnostics
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Drive functions

Advertisement

Table of Contents
loading