9.13

Additional controls for Active Infeed

Function description
With the "Supplementary closed-loop control" function module, parameterizable band-stop
filters (Page 40) can be used with whose help path resonances can be attenuated.
The main application for these band-stop filters is in weak line supplies in which the resonance
point of the line filter can drop to one quarter of the controller frequency.
Activating the function module
To activate the function module, proceed as follows:
1. Select the infeed unit in the project navigator and open the "Properties" shortcut menu.
The "Object properties" dialog then opens.
2. Click the "Function modules" tab.
3. Activate the "Additional closed-loop controls" function module in the function modules
selection with a mouse click.
Parameter r0108.03 indicates whether the function module has been activated.
Function diagrams (see SINAMICS S120/S150 List Manual)
● 8940
● 8946
Drive functions
Function Manual, 06/2019, 6SL3097-5AB00-0BP2
Active Infeed - controller modulation depth reserve / controller DC link voltage
(p3400.0 = 0)
Active Infeed - current precontrol / current controller / gating unit (p3400.0 = 0)
Function modules
9.13 Additional controls for Active Infeed