Chapter 6 Control Mode Of Operation; Selection Of Operation Mode - Delta ASDA-M Series User Manual

Delta ultimate integrated ac servo drive with excellent performance
Hide thumbs Also See for ASDA-M Series:
Table of Contents

Advertisement

Chapter 6 Control Mode of

6.1 Selection of Operation Mode

Three basic operation modes are provided in this servo drive, position, speed and torque.
Users can use single mode (only in one-mode control) and dual mode to control. The
following table lists all operation mode and description.
Mode Name
Position mode
(Terminal input)
Position mode
(Register input)
Single
Mode
Speed mode
Speed mode
(No analog input)
Revision December, 2014
Setting
Short
Name
Code
The servo drive receives position command
and commands the motor to the target
PT
00
position. The position command is input via
terminal block and receives pulse signal.
The servo drive receives position command
and commands the motor to the target
PR
01
position. The position command is issued by
register (64 sets of register in total) and uses
DI signal to select the register.
The servo drive receives speed command
and commands the motor to the target
speed. The speed command can be issued
S
02
by register (3 sets of registers in total) or the
external analog voltage (-10V ~ +10V). DI
signal is used to select the command source.
The servo drive receives speed command
and commands the motor to the target
speed. The speed command is issued by
Sz
04
register (3 sets of registers in total) and
cannot be issued by the external terminal
block. DI signal is used to select the
command source.
Operation
Description
6-1