Chapter 5 Trial Operation and Tuning
ASDA-M

5.3 JOG Trial Run without Load

It is very convenient to test the motor and servo drive with the method of JOG trial run
without load since the extra wiring is unnecessary. For safety reasons, it is recommended
to set JOG at low speed. Please see the following descriptions.
STEP 1: Use software setting to Servo ON. Select the desired JOG axis and set parameter
P2-30 to 1. This setting is to force the servo ON through software.
STEP 2: Set P4-05 as JOG speed (unit: r/min). After setting the desired JOG speed, press
the SET Key, the servo drive will enter JOG mode.
STEP 3: Press the MODE Key to exit JOG mode.
In this example, the JOG speed is adjusted from 20r/min to 100r/min.
Motor rotates in
forward direction
Speed
Motor Stops
0
Motor rotates in
reverse direction
Press
Press
Release
If the servo motor does not rotate, please make sure the wiring of U, V, W terminals and encoder is correct
If the servo motor does not rotate properly, please make sure the phase of U, V, W cables is connected correctly.