Trial Run without Load (Position Mode)

Before the trial run without load, firmly secure the motor base so as to avoid the danger
cause by the reaction of motor operation.
STEP 1:
Set the control mode of the servo drive to position mode.
Firstly select the desired axis for speed test, and set parameter P1-01 to 1. Then, re-power
on the servo drive.
STEP 2: In position mode, the digital input settings of trial run are as follows:
Parameter
Digital Input
Setting Value
DI1
P2-10 = 101
DI2
P2-11 = 108
DI3
P2-12 = 111
DI4
P2-13 = 112
DI5
P2-14 = 102
DI6
P2-15 = 0
The above table disables the function of emergency stop (DI6) (the default setting), thus,
set P2-15 to 0 (Disabled). The digital input of Delta's servo drive can be programmed by
users. When programming digital input, please refer to the description of DI code.
The default setting includes the function of negative limit, positive limit and emergency stop,
therefore, after the setting is completed, if there is any alarm occurs, please re-power on
the servo drive or switch ON DI5 to clear the alarm. Please refer to Chapter 5.2.
Revision December, 2014
Symbol
Function Description
SON
Servo ON
CTRG
Torque limit
Position command
POS0
Position command
POS1
ARST
Alarm reset
Disabled
Invalid DI function
Chapter 5 Trial Operation and Tuning
CN1 Pin No
DI1- = 9
DI2- = 10
DI3- = 34
selection
DI4- = 8
selection
DI5- = 33
-
5-9