6-2-2. Muting System Wiring Examples

6-2-2-1. Standard Muting Mode/Exit-Only Muting Mode

[Wiring Example]
F39-JG
C-L
S1
S1: Test switch
S2: Lockout reset switch, override switch or override cancel switch
S3, S4: Muting sensor
PLC: Programmable logic controller (Used for monitoring only.
NOT related to safety system.)
Function
EDM
EDM Disabled (factory default setting)
Interlock
Auto Reset (factory default setting)
Operating Range
Long : Open the OPERATING RANGE SELECT INPUT line of the emitter or connect the line to 24 VDC.
Selection
Standard Muting Mode
When not using the Intelligent Tap or the SD Manager 3, perform wiring according to the wiring diagram.
(factory default setting)
N/A
Exit-Only Muting Mode
N/A
External Test used
Connect the TEST line of the emitter to 24V/0V of the emitter via a test switch (NO contact). *10
N/A
Optical Synchronization
Open the COM(+) and COM(-) lines of the emitter.
Timing chart
Beam state: Unblocked
Blocked
Test switch (S1)
MUTE A
MUTE B
OSSD
• When a functional earth is necessary, wire an earth cable according to the example in 6-2-1-1. Auto Reset Mode with
Optical Synchronization and EDM Unused. Also refer to 5-4-4. Functional Earth Connection for more information.
F39-JG
C-D
S2
S3
S4
*4
IN
IN1
Safety controller
PLC *5
*6 *7
DIP switch
-
-
-
*1. Reverse the polarity of the power supply when using in the NPN system. Select
a PLC and a safety controller of PNP or NPN type according to the system of
your application.
*2. Connect the line to 0 VDC if Operating Range Selection is used in Short Mode.
*3. Also used as OVERRIDE INPUT line.
*4. Make sure to connect an override cancel switch to the RESET line when using
the override function. Otherwise the override state may not be released by the
override cancel switch, resulting in serious injury.
*5. When connecting to the PLC, the output mode must be changed with the SD
Manager 3 according to your application. Refer to Chapter 4 Setting with SD
Manager 3 for more information on setting this function by the SD Manager 3.
*6. Refer to 6-3. Connectable Safety Control Units for more information.
*7. The safety controller and the F3SG-SR must share the power supply or be
connected to the common terminal of the power supply.
*8. This is the case for a PELV circuit.
*9. Set the function with the SD Manager 3, restore the settings to the F3SG-SR,
and perform wiring according to the wiring diagram.
*10.This wiring example shows light emission stop when connected to 24 VDC with
PNP setting, and light emission stop when connected to 0 VDC with NPN
setting. If TEST switch is not needed, refer to 2-6. External Test.
Input/Output Circuit and Applications
Intelligent Tap
24 VDC
*8
IN2
: Indicates a switch position
Setting
SD Manager 3
[External device monitoring] : Disable *9
[Start interlock] : Disable
[Restart interlock] : Disable *9
[Operating Range Selection] : Long mode *9
[Muting] : Enable
[Muting mode] : Standard Muting (Installation
Example1/2) *9
[Muting] : Enable
[Muting mode] : Exit-Only Muting *9
[External test signal inversion] : Disable
Needed *9
Wiring for NPN *1
24 VDC
F3SG-SR
327
User's Manual