(3) DIP Switch Setting
Before powering the F3SG-SR, set the DIP Switch Position 1 at ON (Lock), Position 2 at ON (DIP
Switch Enabled) and Position6 at ON and 7 at OFF (Fixed Blanking Enabled). And then power the
F3SG-SR.
The Intelligent Tap restores the settings configured by the DIP Switch, to the F3SG-SR. When the
Restoration process is complete successfully, restart the F3SG-SR and check if the F3SG-SR
operates normally.
Block the target Fixed Blanking zone by an object. Do not remove the object until the Step (5) is
complete.
Refer to 3-4. LED Indicators on Intelligent Tap for more information.
(4) Transition to Teach-in Mode
Press and hold the Push Switch (for 3 s or longer) or turn the muting input A ON (for 3 s or longer) to
make the F3SG-SR transition to Teach-in mode.
When the F3SG-SR transitioned to Teach-in mode, the CFG indicator of the F3SG-SR blinks.
(The mode transition to Teach-in mode does not occur if the setting of the DIP Switch is configured as
"Unlock", "DIP Switch Disabled" or "Fixed Blanking Disabled".)
Indicator status in Teach-in mode
F3SG-SR
LED Indicator
SEQ
OFF
CFG
Blinking
Area blocked by
ABI
blocking object is
illuminated in red
(5) Teach-In and Check Processes
When it is ensured that the F3SG-SR is in the Teach-in mode, press the Push Switch (for within 1 s) or
turn the muting input A ON (for within 1 s) to activate the scanning of the blocked area and
automatically configure the setting related to the Fixed Blanking.
The F3SG-SR judges if the setting is valid or not.
If the setting is invalid
*2
, SEQ indicator blinks. In this case, try the steps again from (4).
*1 The Fixed Blanking zone is configured to include one additional beam outside the actually blocked
beams. Two beams on both ends are configured as allowable beams.
Upper
Upper
11th beam
10th beam
5th beam
4th beam
Lower
Lower
Status
Allowable beam (10th and 11th beams)
Fixed Blanking zone (4th to 11th beams)
Allowable beam (4th and 5the beams)
Setting with Intelligent Tap
*1
E
F3SG-SR
143
User's Manual

Advertisement

Table of Contents
loading

This manual is also suitable for:

F3sg-sr seriesF3sg-sra series

Table of Contents