Wiring and Installation
<EMITTER>
<RECEIVER>
- The angle adjustment range is ±22.5° when using the Top/Bottom Brackets only.
- The angle adjustment range is ±15° when using the Top/Bottom Brackets and Adjustable Side-Mount Bracket(s)
together.
- The ABI indicators are for the F3SG-SRA only. The TOP and BTM indicators are for the F3SG-SRB only.
- The ABI indicators of both emitter and receiver are illuminated in the case the Wired Synchronization is enabled. Only
the ABI indicators of the receiver are illuminated in the case the Optical Synchronization is enabled.
- It is recommended to use the Light Level Monitoring with the SD Manager 3 for beam alignment. Refer to Chapter 4
Setting with SD Manager 3 for more information.
- The ABI indicators (green) will not be illuminated if the blanking function is used and there is a blocking object in the
detection zone. Perform beam alignment according to the step No. 7 after setting the blanking function.
8.
Securely tighten the Alignment Screws of the Top/Bottom Bracket and Adjustable Side-Mount Bracket
to fix the bracket to the sensor housing. The recommended torque to tighten the Alignment Screws is
3.0 N•m. (Fig. 10)
Securely tighten
Alignment Screw
Tightening screws with a torque that considerably exceeds the recommended torque may cause failure.
F3SG-SR
288
User's Manual
<Backside mounting>
Securely tighten
Alignment Screw
(Top/Bottom Bracket)
Securely tighten
Alignment Screw
(Top/Bottom Bracket)
Marking on the side (Emitter)
Marking on the side (Receiver)
Fig. 9
Securely tighten
Alignment Screw
(Top/Bottom Bracket)
Securely tighten
Alignment Screw
Securely tighten
Alignment Screw
(Top/Bottom Bracket)
Fig. 10
"EMITTER" mark
"RECEIVER" mark
<Side mounting>