2-20-2. Factory Default Setting
The Operating Range Selection is configured as Long Mode. The operating range for the long mode
setting is from 0.3 to 20 m for F3SG-SR 25-mm/45-mm/85-mm detection capability model and from 0.3
m to 10 m for F3SG-SR 14-mm detection capability model.
2-20-3. Setting with Intelligent Tap
The user can select the mode of Operating Range Selection by the DIP Switch.
Make sure the Position 2 of the DIP Switch is set at ON (DIP Switch Enabled) to activate the settings by the DIP Switch.
Refer to Chapter 3 Setting with Intelligent Tap for more information on setting this function by the Intelligent Tap.
2-20-4. Setting with SD Manager 3
The user can make changes to the settings of this function by the SD Manager 3.
Function name
Operating Range Selection
It is recommended that the Position 2 of the DIP Switch be set at OFF (DIP Switch Disabled).
Refer to Chapter 4 Setting with SD Manager 3 for more information on changing functions by SD Manager 3.
Description
Select the operating range.
System Operation and Functions
Initial value
Configurable value or numerical range
Long mode
Short mode/Long mode
E
F3SG-SR
111