Checking That Hazardous Parts Stop While The Machine Operates - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Checklists
 When the External Test function is used:
When PNP is selected, the OSSD indicator turns red when the TEST line is short-circuited to 9 V to Vs.
When NPN is selected, the OSSD indicator turns red when the TEST line is short-circuited to 0 to 3 V.
 When the External Device Monitoring function is used:
When the RESET line is open the OSSD indicator remains red regardless of the beam state of the
F3SG-SR.
 When the Start Interlock function is used:
When the F3SG-SR is turned ON and the F3SG-SR is unblocked, the OSSD indicator remains red.
The reset input turns the OSSD indicator to green.
 When the Restart Interlock function is used:
When the OSSD indicator is green and the F3SG-SR is blocked and then returned to unblocked
state, the OSSD indicator remains red. The reset input turns the OSSD indicator to green.
 When the Muting function is used, minimum muting time limit required must be set.
 When the Muting function's operation mode is Exit-Only Muting mode, minimum muting end wait time
required must be set.
 Under the MUTING state, a signal that indicates the MUTING state must be given from the AUX line.
 When the Override function is used, the minimum override time limit required must be set.
 Under the OVERRIDE state, a signal that indicates the OVERRIDE state must be given from the AUX
line.

7-1-1-4. Checking that Hazardous Parts Stop While the Machine Operates

 The hazardous parts stop immediately when a test rod is inserted into the detection zone at 3
positions: "directly in front of the emitter", "directly in front of the receiver", and "between the emitter
and receiver". (Use the appropriate test rod.)
 The hazardous parts remain stopped as long as the test rod is in the detection zone.
 The hazardous parts stop when the power of the F3SG-SR is turned OFF.
 The actual response time of the whole machine is equal to or less than the calculated value.
F3SG-SR
336
User's Manual