Muting Statistics Information - Omron F3SG-SRB Series User Manual

Hide thumbs Also See for F3SG-SRB Series:
Table of Contents

Advertisement

Setting with SD Manager 3

4-4-2. Muting Statistics Information

This function can be used only when the F3SG-SR is connected to the Intelligent Tap and a PC.
This function logs and visualizes conditions of F3SG-SR muting operations to help the user adjust
settings of muting input time difference. Also, its statistic calculation allows for optimal settings with
reduced test runs.
On the Top page, click the icon below.
The screen below is displayed.
No.
1
Start (stop) online
monitoring
2
Retrieve log
3
Open analysis data
4
Save analysis data
5
Clear log
6
Timing chart
7
Muting input time
difference analysis table
8
Description on muting
input time difference
analysis table
9
Standard deviation setting The range of variation of assumed data can be selected from 2.6 , 3.0 and 6.0 .
F3SG-SR
224
User's Manual
Function
Retrieves muting input time difference information from the F3SG-SR in real time and
displays it in the analysis data area (No. 10).
Obtains the muting input time difference information saved in F3SG-SR and displays it as
Analysis Data (No. 10) and displays the graph as Graph (No. 11). Pressing this button
switches the safety outputs to the OFF state and the operating state to [Setting state].
Opens a .cvs file saved by the operation (No. 4).
Saves data displayed in the analysis data area (No. 10) as a .csv file. The data saved also
includes other muting input time difference information and sensor information.
Clears muting time logs saved in the F3SG-SR.
Displays a timing chart of time analyzed.
Displays minimum and maximum values of muting setting parameter, assumed data and
measured data, and judgment results on these values.
Displays meanings of abbreviations and judgment results in the table.
A.D.: Assumed Data (the value calculated from M.D. using the standard deviation setting.
The value of zero or less is handled as zero.)
M.D.: Measured Data (the measured value of the time difference from muting input A to
muting input B)
Description